PRODUCTION LEAD TIMESStock 2 weeks min//Custom 6 weeks min//Canopies 6 weeks min
Support documents

EVO2 · TECHNICAL GUIDE

SAFE / MARD System

Components, preparation, assembly, packing and maintenance of the SAFE MARD for the EVO harness container.

Marine eye ripcord · post-June 2025
01

Components

  1. Ripcord with pin

  2. RSL lanyard with safety pin and marine eye

  3. SAFE/MARD lanyard

  4. Retention bungee

  5. Lanyard with reserve pin

Component numbers correspond to the list above.
Component numbers correspond to the list above.
02

Preparing the SAFE / MARD

  1. Lark’s head the SAFE lanyard through the retention bungee.

  2. Tighten by pulling both ends.

Pass the SAFE lanyard through the retention bungee.
Pass the SAFE lanyard through the retention bungee.
Form the lark’s head.
Form the lark’s head.
Pull both ends tight.
Pull both ends tight.
  1. Lark’s head the opposite end of the SAFE lanyard with the black end of the RSL.

  2. Secure by pulling both ends tight.

Connect the opposite end of the SAFE lanyard to the RSL.
Connect the opposite end of the SAFE lanyard to the RSL.
Form the lark’s head at the RSL.
Form the lark’s head at the RSL.
Secure the connection by pulling both ends tight.
Secure the connection by pulling both ends tight.
  1. Lark’s head the reserve pin lanyard through the RSL tab.

Pass the reserve pin lanyard through the RSL tab.
Pass the reserve pin lanyard through the RSL tab.
Form the lark’s head at the RSL tab.
Form the lark’s head at the RSL tab.
Reserve pin lanyard connected to the RSL tab.
Reserve pin lanyard connected to the RSL tab.
03

Assembly & Packing

  1. Fold the bridle at the green marking (bartack) and insert 10” (25 cm) of safety thread.

Green marking on the bridle.
Green marking on the bridle.
SAFE/MARD assembly reference.
SAFE/MARD assembly reference.
  1. Insert the MARD bungee through the grommet from the bottom.

  2. Insert the hemostat through both channels and the MARD bungee in the opposite direction of the arrows.

Bungee and channels.
Bungee and channels.
Hemostat through the SAFE/MARD assembly.
Hemostat through the SAFE/MARD assembly.
  1. Fold the bridle into a tip at the green marking.

  2. Grab the folded bridle tip with the hemostat and pull it through both channels and the MARD bungee.

  3. Align the green tip with the green markings on the sides of the SAFE/MARD.

Bridle tip at the green marking.
Bridle tip at the green marking.
Pull the bridle tip through both channels and the MARD bungee.
Pull the bridle tip through both channels and the MARD bungee.
Green tip aligned with the green side markings.
Green tip aligned with the green side markings.
  1. Insert the hemostat through the Spectra loop to ease insertion of the safety thread.

  2. Insert the safety thread through the Spectra loop and secure it with a surgeon’s knot and a lock knot.

  3. This ensures that the tip will not be disengaged.

  4. The SAFE/MARD is ready to install. The yellow RSL lanyard is used in the photos only to distinguish it from the SAFE/MARD lanyard.

Safety-thread detail.
Safety-thread detail.
Secured safety thread.
Secured safety thread.
SAFE/MARD assembly detail.
SAFE/MARD assembly detail.
  1. Close flap #1. Fold the bridle until the SAFE/MARD is positioned under flap #2. Close flap #2.

  2. After flap #2 is closed, make sure the SAFE/MARD and the folds are in place.

EVO2 marine eye configuration: final assembly reference.
EVO2 marine eye configuration: final assembly reference.
04

Maintenance

The retention bungee (4 mm elastic with neon green sheeting) must be replaced if, after a deployment, the bungee is damaged or one of the stitches on the sheeting is broken.

Every EVO comes with three bungees. Spare bungees can be ordered through order@flyfirebird.com.

YOUR SELECTION

Your Cart (0)

Start with What You Need.

Your selections will stay in this browser.

Explore Spare Parts